{"title":"Cable \u0026 Wire","description":"","products":[{"product_id":"cto_1thhnstr","title":"#1 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). 4 AWG THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003cbr\u003eCopper wire, THWN, building wire, hook up wire, conduit wire, bathtub wire, lighting wire, nylon copper wire, construction cable, etc...\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003cbr\u003eA tough, polyamide, Nylon outer covering per UL-1063 and UL-83.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eUnderwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003eAWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003eASTM Stranding Class B3, B8, B787\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNEMA WC70\/ICEA S-95-658\u003cbr\u003eInstitute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003eColor-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e1 AWG\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e19\u003cbr\u003e\u003cb\u003eCross Section Area (mm2):\u003c\/b\u003e42.40\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness (Conductor):\u003c\/b\u003e1.270 mm \/ 0.050 inches\u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e0.180 mm \/ 0.007 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e11.05 mm \/ 0.435 inches\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e0.316 lbs per ft\u003cbr\u003e\u003cb\u003eAlowable Ampacity:\u003c\/b\u003e110 Amps at 60℃ \/ 130 Amps at 75℃ \/ 150 Amps at 90℃\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39861455159475,"sku":"4994","price":3.65,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":39861455323315,"sku":"221086","price":3.74,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39861455257779,"sku":"32144","price":3.23,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":39861455388851,"sku":"36017","price":3.17,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39861455126707,"sku":"35966","price":3.4,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39861455356083,"sku":"1193","price":3.38,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39861455192243,"sku":"221085","price":3.72,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39861455290547,"sku":"221087","price":3.6,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39861455225011,"sku":"7799","price":3.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_585f8314-e274-426e-902d-151e83e8fa0d.jpg?v=1738617351"},{"product_id":"cto_2thhnstr","title":"#2 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e - Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e - AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e - ASTM Stranding Class B3, B8, B787\u003cbr\u003e - Federal Specification A-A-59544\u003cbr\u003e - Canadian Standards Association C22.2 No. 75\u003cbr\u003e - NEMA WC70\/ICEA S-95-658\u003cbr\u003e - Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 2\/0\u003cbr\u003eNumber of Strands: 19\u003cbr\u003eCross Section Area (mm2): 67.40\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.270 mm \/ 0.050 inches\u003cbr\u003eNylon Jacket Thickness: 0.180 mm \/ 0.007 inches\u003cbr\u003eOutside Diameter: 13.16 mm \/ 0.518 inches\u003cbr\u003eWeight: 0.488 lbs per ft\u003cbr\u003eAllowable Ampacity: 145 Amps at 60ºC \/ 175 Amps at 75ºC \/ 195 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39861455945907,"sku":"41204","price":3.4,"currency_code":"USD","in_stock":false},{"title":"Blue","offer_id":39861456109747,"sku":"111392","price":2.98,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39861456044211,"sku":"155988","price":3.17,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":39861456175283,"sku":"155990","price":2.69,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39861455913139,"sku":"20876","price":2.96,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39861456142515,"sku":"155989","price":3.02,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39861455978675,"sku":"111391","price":3.05,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39861456076979,"sku":"111393","price":3.06,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39861456011443,"sku":"156006","price":2.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/Black-stranded-thhn_2051c099-239b-4ea7-896f-c4a1eda2e24c.jpg?v=1626895098"},{"product_id":"cto_6thhnstr","title":"#6 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). 6 AWG THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type AWM conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations. Most common building wire used often on sub-panels, hot tubs \u0026amp; jacuzzis.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003cbr\u003eCopper wire, THWN-2 Wire, building wire, hook up wire, conduit wire, hot tub wire, lighting wire, nylon copper wire, construction cable, 6 gauge wire\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 6 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003cbr\u003eA tough, polyamide, Nylon outer covering per UL-1063 and UL-83.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eUnderwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003eAWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003eASTM Stranding Class B3, B8, B787\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNEMA WC70\/ICEA S-95-658\u003cbr\u003eInstitute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstrction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003eColor-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e6 AWG\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e19\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness (Conductor):\u003c\/b\u003e0.760 mm \/ 0.030 inches\u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e0.130 mm \/ 0.005 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e6.30 mm \/ 0.248 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.109 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e55 Amps at 60℃ \/ 65 Amps at 75\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39861457944755,"sku":"16938","price":1.37,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":39861458141363,"sku":"161483","price":1.29,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39861458043059,"sku":"160764","price":1.32,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":39861458108595,"sku":"194881","price":1.34,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39861457911987,"sku":"13680","price":1.31,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39861458174131,"sku":"160763","price":1.32,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39861457977523,"sku":"160761","price":1.36,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39861458075827,"sku":"161484","price":1.36,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39861458010291,"sku":"160762","price":1.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_135682b2-a51b-40de-a2ff-64ac68d3d1fb.jpg?v=1738617321"},{"product_id":"cto_1-0thhnstr","title":"1\/0 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e - AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e - ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e- Size: 1\/0\u003cbr\u003e- Number of Strands: 19\u003cbr\u003e- Cross Section Area (mm2): 53.5\u003cbr\u003e- PVC Insulation Thickness (Conductor): 1.270 mm \/ 0.050 inches\u003cbr\u003e- Nylon Jacket Thickness: 0.180 mm \/ 0.007 inches\u003cbr\u003e- Outside Diameter: 12.04 mm \/ 0.007 inches\u003cbr\u003e- Weight: 0.398 lbs per ft\u003cbr\u003eAllowable Ampacity: 125 Amps at 60ºC \/ 150 Amps at 75ºC \/ 170 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39861458239667,"sku":"36796","price":4.09,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":39861458403507,"sku":"108451","price":3.19,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39861458337971,"sku":"108448","price":3.22,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":39861458469043,"sku":"108452","price":3.3,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39861458206899,"sku":"63378","price":3.99,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39861458436275,"sku":"108449","price":3.15,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39861458272435,"sku":"108480","price":4.07,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39861458370739,"sku":"111401","price":3.57,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39861458305203,"sku":"108450","price":3.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_23f97874-ac73-4649-a4b3-60b85ac3e3b6.jpg?v=1738615380"},{"product_id":"cto_2-0thhnstr","title":"2\/0 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e - Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e - AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e - ASTM Stranding Class B3, B8, B787\u003cbr\u003e - Federal Specification A-A-59544\u003cbr\u003e - Canadian Standards Association C22.2 No. 75\u003cbr\u003e - NEMA WC70\/ICEA S-95-658\u003cbr\u003e - Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 2\/0\u003cbr\u003eNumber of Strands: 19\u003cbr\u003eCross Section Area (mm2): 67.40\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.270 mm \/ 0.050 inches\u003cbr\u003eNylon Jacket Thickness: 0.180 mm \/ 0.007 inches\u003cbr\u003eOutside Diameter: 13.16 mm \/ 0.518 inches\u003cbr\u003eWeight: 0.488 lbs per ft\u003cbr\u003eAllowable Ampacity: 145 Amps at 60ºC \/ 175 Amps at 75ºC \/ 195 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39861458763955,"sku":"17442","price":5.74,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":39861458927795,"sku":"111404","price":5.17,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39861458862259,"sku":"156007","price":5.32,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":39861458993331,"sku":"156010","price":5.32,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39861458731187,"sku":"153360","price":5.48,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39861458960563,"sku":"156008","price":5.06,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39861458796723,"sku":"111403","price":4.35,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39861458895027,"sku":"111402","price":5.15,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39861458829491,"sku":"156009","price":5.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_46a097e2-f6c8-4350-aa86-51c09a3ae76e.jpg?v=1738617419"},{"product_id":"cto_3-0thhnstr","title":"3\/0 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003cb\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e- AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e- ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers\u003c\/b\u003e\u003c\/b\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 3\/0\u003cbr\u003eNumber of Strands: 19\u003cbr\u003eCross Section Area (mm2): 85.00\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.270 mm \/ 0.050 inches\u003cbr\u003eNylon Jacket Thickness: 0.180 mm \/ 0.007 inches\u003cbr\u003eOutside Diameter: 14.43 mm \/ 0.568 inches\u003cbr\u003eWeight: 0.603 lbs per ft\u003cbr\u003eAllowable Ampacity: 165 Amps at 60ºC \/ 200 Amps at 75ºC \/ 225 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39861459353779,"sku":"37080","price":6.92,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":39861459517619,"sku":"108457","price":7.94,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39861459452083,"sku":"108453","price":6.85,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":39861459583155,"sku":"108456","price":5.82,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39861459321011,"sku":"61684","price":6.65,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39861459550387,"sku":"108454","price":5.22,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39861459386547,"sku":"108482","price":7.98,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39861459484851,"sku":"220225","price":7.98,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39861459419315,"sku":"108455","price":6.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/Black-stranded-thhn_91dbacac-0f46-4ce9-abba-97e9483e61c5.jpg?v=1626895085"},{"product_id":"cto_4-0thhnstr","title":"4\/0 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e- AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e- ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 4\/0\u003cbr\u003eNumber of Strands: 19\u003cbr\u003eCross Section Area (mm2): 107.00\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.270 mm \/ 0.050 inches\u003cbr\u003eNylon Jacket Thickness: 0.180 mm \/ 0.007 inches\u003cbr\u003eOutside Diameter: 15.85 mm \/ 0.624 inches\u003cbr\u003eWeight: 0.731 lbs per ft\u003cbr\u003eAllowable Ampacity: 195 Amps at 60ºC \/ 230 Amps at 75ºC \/ 260 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39861459812531,"sku":"13768","price":8.18,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":39861459976371,"sku":"190102","price":8.18,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39861459910835,"sku":"156011","price":7.31,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":39861460041907,"sku":"156014","price":6.76,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39861459779763,"sku":"10950","price":7.86,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39861460009139,"sku":"156012","price":6.7,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39861459845299,"sku":"165455","price":7.89,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39861459943603,"sku":"190103","price":7.45,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39861459878067,"sku":"156013","price":6.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/Black-stranded-thhn_f2d02f8b-641f-4de4-bf77-dc815fcac1fb.jpg?v=1626895085"},{"product_id":"cto_10-3mc","title":"10\/3 Metal Clad (MC) Cable with Ground, Aluminium Armor and Solid Copper Conductors Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003eType MC Cable is constructed with soft-drawn copper, Type THHN\/THWN conductors rated 90Deg dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMetal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Meets UL 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003e- Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)\u003cbr\u003e- Meets UL 1569: Metal Clad Cables\u003cbr\u003e- Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords\u003cbr\u003e- Meets UL 2256: Wire and Cable Test Methods\u003cbr\u003e- Designated Type MC per NEC Article 330\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSize:\u003c\/b\u003e 10 AWG\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e 0.584 inches\n\u003cbr\u003e\u003cb\u003eAmpere Rating THHN:\u003c\/b\u003e 30\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":39861473935539,"sku":"285394","price":3.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/12-3-MC-cable_ddca7d98-cafd-4988-9b83-d9a00b73a757.jpg?v=1664565873"},{"product_id":"reel_12thhnstr","title":"#12 Stranded Copper THHN Building Wire","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTHHN and THWN is a multi-purpose building wire used in conduit and cable trays for service, feeders and branch circuits in commercial and industrial applications. It is also used as a conductor in NM-B, UF-B, SER, SEU and MC. THHN is rated for 600-Volt and has a heat capacity of up to 90Deg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC).Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90Deg or not to exceed 75Deg in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90Deg, or not to exceed 60Deg in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105Deg in dry locations.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnderwriters Laboratories Standards UL-83, UL-1063, UL-758 \u003cbr\u003eAWM Spec 1316, 1317, 1318, 1319, 1320, 1321 \u003cbr\u003eASTM Stranding Class B3, B8, B787 \u003cbr\u003eFederal Specification A-A-59544 \u003cbr\u003eCanadian Standards Association C22.2 No. 75 \u003cbr\u003eNEMA WC70\/ICEA S-95-658 \u003cbr\u003eInstitute of Electrical and Electronics Engineers\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSize:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 19 \u003cbr\u003e\u003cb\u003eCross Section Area (mm2):\u003c\/b\u003e 3.31 \u003cbr\u003e\u003cb\u003ePVC Insulation Thickness (Conductor):\u003c\/b\u003e 0.380 mm \/ 0.015 inches \u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e 0.100 mm \/ 0.004 inches \u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e 3.23 mm \/ 0.127 inches \u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 20 Amps at 60degC \/ 20 Amps at 75degC \/ 20 Amps at 90degC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black \/ 500","offer_id":39862221996211,"sku":"38687","price":163.15,"currency_code":"USD","in_stock":true},{"title":"Black \/ 2500","offer_id":39862222028979,"sku":"35316","price":699.0,"currency_code":"USD","in_stock":true},{"title":"Blue \/ 500","offer_id":39862222061747,"sku":"38747","price":143.72,"currency_code":"USD","in_stock":true},{"title":"Blue \/ 2500","offer_id":39862222094515,"sku":"1967","price":644.97,"currency_code":"USD","in_stock":true},{"title":"Brown \/ 500","offer_id":39862222127283,"sku":"39136","price":136.93,"currency_code":"USD","in_stock":true},{"title":"Brown \/ 2500","offer_id":39862222160051,"sku":"40101","price":713.83,"currency_code":"USD","in_stock":true},{"title":"Gray \/ 500","offer_id":39862222192819,"sku":"724","price":153.02,"currency_code":"USD","in_stock":true},{"title":"Gray \/ 2500","offer_id":39862222225587,"sku":"17747","price":526.27,"currency_code":"USD","in_stock":true},{"title":"Green \/ 500","offer_id":39862222258355,"sku":"658","price":153.24,"currency_code":"USD","in_stock":true},{"title":"Green \/ 2500","offer_id":39862222291123,"sku":"7284","price":742.43,"currency_code":"USD","in_stock":true},{"title":"Orange \/ 500","offer_id":39862222323891,"sku":"6626","price":139.13,"currency_code":"USD","in_stock":true},{"title":"Orange \/ 2500","offer_id":39862222356659,"sku":"129","price":617.16,"currency_code":"USD","in_stock":true},{"title":"Red \/ 500","offer_id":39862222389427,"sku":"8129","price":145.88,"currency_code":"USD","in_stock":true},{"title":"Red \/ 2500","offer_id":39862222422195,"sku":"41167","price":696.73,"currency_code":"USD","in_stock":true},{"title":"Tan \/ 500","offer_id":39862222454963,"sku":"83806","price":69.72,"currency_code":"USD","in_stock":false},{"title":"White \/ 500","offer_id":39862222487731,"sku":"5141","price":150.96,"currency_code":"USD","in_stock":true},{"title":"White \/ 2500","offer_id":39862222520499,"sku":"30951","price":721.31,"currency_code":"USD","in_stock":true},{"title":"Yellow \/ 500","offer_id":39862222553267,"sku":"13500","price":136.84,"currency_code":"USD","in_stock":true},{"title":"Yellow \/ 2500","offer_id":39862222586035,"sku":"1545","price":731.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/71Ey90AMMxL._SL1500.jpg?v=1743025800"},{"product_id":"reel_12thhnsld","title":"#12 Solid Copper THHN Building Wire","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eTHHN and THWN is a multi-purpose building wire used in conduit and cable trays for service, feeders and branch circuits in commercial and industrial applications. It is also used as a conductor in NM-B, UF-B, SER, SEU and MC. THHN is rated for 600-Volt and has a heat capacity of up to 90Deg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC).Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90Deg or not to exceed 75Deg in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90Deg, or not to exceed 60Deg in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105Deg in dry locations.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnderwriters Laboratories Standards UL-83, UL-1063, UL-758 \u003cbr\u003eAWM Spec 1316, 1317, 1318, 1319, 1320, 1321 \u003cbr\u003eASTM Stranding Class B3, B8, B787 \u003cbr\u003eFederal Specification A-A-59544 \u003cbr\u003eCanadian Standards Association C22.2 No. 75 \u003cbr\u003eNEMA WC70\/ICEA S-95-658 \u003cbr\u003eInstitute of Electrical and Electronics Engineers\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSize:\u003c\/b\u003e 12 AWG \u003cbr\u003e\u003cb\u003eStranding:\u003c\/b\u003e Solid \u003cbr\u003e\u003cb\u003eCross Section Area (mm2):\u003c\/b\u003e 3.31 \u003cbr\u003e\u003cb\u003ePVC Insulation Thickness (Conductor):\u003c\/b\u003e 0.380 mm \/ 0.015 inches \u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e 0.100 mm \/ 0.004 inches \u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e 3.05 mm \/ 0.120 inches \u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 20 Amps at 60degC \/ 20 Amps at 75degC \/ 20 Amps at 90degC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black \/ 500","offer_id":39862223470771,"sku":"23859","price":132.25,"currency_code":"USD","in_stock":true},{"title":"Black \/ 2500","offer_id":39862223503539,"sku":"1062","price":694.37,"currency_code":"USD","in_stock":true},{"title":"Blue \/ 500","offer_id":39862223536307,"sku":"23910","price":136.42,"currency_code":"USD","in_stock":true},{"title":"Blue \/ 2500","offer_id":39862223569075,"sku":"8828","price":567.0,"currency_code":"USD","in_stock":true},{"title":"Brown \/ 500","offer_id":39862223601843,"sku":"24313","price":123.75,"currency_code":"USD","in_stock":true},{"title":"Brown \/ 2500","offer_id":39862223634611,"sku":"6374","price":576.7,"currency_code":"USD","in_stock":true},{"title":"Gray \/ 500","offer_id":39862223667379,"sku":"27528","price":126.67,"currency_code":"USD","in_stock":true},{"title":"Gray \/ 2500","offer_id":39862223700147,"sku":"27720","price":607.03,"currency_code":"USD","in_stock":true},{"title":"Green \/ 500","offer_id":39862223732915,"sku":"27482","price":140.04,"currency_code":"USD","in_stock":true},{"title":"Green \/ 2500","offer_id":39862223765683,"sku":"18586","price":586.03,"currency_code":"USD","in_stock":true},{"title":"Orange \/ 500","offer_id":39862223798451,"sku":"33248","price":116.33,"currency_code":"USD","in_stock":true},{"title":"Orange \/ 2500","offer_id":39862223831219,"sku":"2129","price":528.82,"currency_code":"USD","in_stock":true},{"title":"Red \/ 500","offer_id":39862223863987,"sku":"34328","price":139.06,"currency_code":"USD","in_stock":true},{"title":"Red \/ 2500","offer_id":39862223896755,"sku":"6958","price":567.0,"currency_code":"USD","in_stock":true},{"title":"Tan \/ 500","offer_id":39862223929523,"sku":"35274","price":82.0,"currency_code":"USD","in_stock":false},{"title":"White \/ 500","offer_id":39862223962291,"sku":"5159","price":137.01,"currency_code":"USD","in_stock":true},{"title":"White \/ 2500","offer_id":39862223995059,"sku":"11587","price":633.26,"currency_code":"USD","in_stock":true},{"title":"Yellow \/ 500","offer_id":39862224027827,"sku":"39381","price":123.79,"currency_code":"USD","in_stock":true},{"title":"Yellow \/ 2500","offer_id":39862224060595,"sku":"8826","price":557.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/black_20solid_20thhn.jpg?v=1664565553"},{"product_id":"reel_16tffnstr_500","title":"16 AWG TFFN, 26 Stranded Copper Fixture Wire (500 Ft Reel)","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e16-Gauge TFFN Fixture Wire may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the NEC 2. This wire resists heat, moisture, gasoline and oil. UL listed, CSA listed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eType TFFN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the 2008 National Electrical Code. When used as Type TFFN, conductor is suitable for use at temperatures not to exceed 90Deg. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60Deg or dry locations at temperatures not to exceed 90Deg (with ampacity limited to that for 75Deg conductor temperature per NFPA 79). Conductor temperatures not to exceed 105Deg in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL Standard 66\n\u003cbr\u003eNational Electrical Code\n\u003cbr\u003eRoHS Compliant\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSize:\u003c\/b\u003e 16 AWG\n\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 26\n\u003cbr\u003e\u003cb\u003eVinyl Insulation Thickness:\u003c\/b\u003e 0.015 inches\n\u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e 0.004 inches\n\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e 0.099 inches\n\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 0.009 lbs per ft\n\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e TFFN - 8 Amps \/ MTW - 10 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39862226190515,"sku":"33025-500","price":72.25,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":39862226223283,"sku":"33114-500","price":68.75,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39862226256051,"sku":"161824-500","price":64.5,"currency_code":"USD","in_stock":false},{"title":"Gray","offer_id":39862226288819,"sku":"161365-500","price":76.73,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39862226321587,"sku":"37352-500","price":77.02,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39862226354355,"sku":"2779-500","price":86.25,"currency_code":"USD","in_stock":false},{"title":"Pink","offer_id":39862226387123,"sku":"165343-500","price":68.88,"currency_code":"USD","in_stock":true},{"title":"Purple","offer_id":39862226419891,"sku":"48004-500","price":69.39,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39862226452659,"sku":"4054-500","price":71.01,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39862226485427,"sku":"5390-500","price":66.06,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39862226518195,"sku":"9416-500","price":86.25,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/black.jpg?v=1743012454"},{"product_id":"reel_18tffnstr_500","title":"18 AWG TFFN, 16 Stranded Copper Fixture Wire (500 Ft Reel)","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e18-Gauge Stranded TFFN Wire is rated to 600-Volt for use as fixture, machine, tool and appliance wiring. This wire features a nylon jacket over PVC insulation. Features UL and CSA safety listings\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eType TFFN or MTW or AWM may be used as fixture wire, machine tool wiring, or appliance wiring material as specified in the 2008 National Electrical Code. When used as Type TFFN, conductor is suitable for use at temperatures not to exceed 90Deg. When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60Deg or dry locations at temperatures not to exceed 90Deg (with ampacity limited to that for 75Deg conductor temperature per NFPA 79). Conductor temperatures not to exceed 105Deg in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUL Standard 66\u003cbr\u003eNational Electrical Code\u003cbr\u003eRoHS Compliant\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\n\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSize:\u003c\/b\u003e 18 AWG\n\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 16\n\u003cbr\u003e\u003cb\u003eVinyl Insulation Thickness:\u003c\/b\u003e 0.015 inches\n\u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e 0.004 inches\n\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e 0.085 inches\n\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 0.012 lbs per ft\n\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e TFFN - 6 Amps \/ MTW - 7 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":39862226649267,"sku":"165365-500","price":60.48,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":39862226682035,"sku":"165366-500","price":62.95,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":39862226714803,"sku":"165368-500","price":68.18,"currency_code":"USD","in_stock":false},{"title":"Gray","offer_id":39862226747571,"sku":"165370-500","price":52.92,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":39862226780339,"sku":"165367-500","price":55.2,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":39862226813107,"sku":"165369-500","price":54.54,"currency_code":"USD","in_stock":false},{"title":"Pink","offer_id":39862226845875,"sku":"165371-500","price":69.55,"currency_code":"USD","in_stock":false},{"title":"Purple","offer_id":39862226878643,"sku":"165372-500","price":50.16,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":39862226911411,"sku":"84474-500","price":50.4,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":39862226944179,"sku":"84475-500","price":55.44,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":39862226976947,"sku":"48005-500","price":58.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/31P4jOm4hmL.jpg?v=1743007043"},{"product_id":"cto_10-2mc","title":"10\/2 Metal Clad (MC) Cable with Ground, Aluminium Armor and Solid Copper Conductors Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003eType MC Cable is constructed with soft-drawn copper, Type THHN\/THWN conductors rated 90Deg dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMetal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Meets UL 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003e- Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)\u003cbr\u003e- Meets UL 1569: Metal Clad Cables\u003cbr\u003e- Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords\u003cbr\u003e- Meets UL 2256: Wire and Cable Test Methods\u003cbr\u003e- Designated Type MC per NEC Article 330\u003c\/p\u003e\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSize:\u003c\/b\u003e 10 AWG\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e 0.544 inches\n\u003cbr\u003e\u003cb\u003eAmpere Rating THHN:\u003c\/b\u003e 30\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40015135899827,"sku":"284173","price":2.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/12-2-MC-Cable_1419adfb-b554-4fce-8228-6b3be80633e5.jpg?v=1664566123"},{"product_id":"cto_8thhnstr","title":"#8 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). 8 AWG THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 60°C in oil or coolants. Applications requiring Type AWM conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003cbr\u003e8 AWG Copper wire, 8 AWG THWN-2, 8 AWG Building Wire, hook up wire, conduit wire, lighting wire, nylon copper wire, construction cable, 8 Gauge Wire.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eJacket:\u003c\/b\u003e\u003cbr\u003eA tough, polyamide, Nylon outer covering per UL-1063 and UL-83.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eUnderwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003eAWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003eASTM Stranding Class B3, B8, B787\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNEMA WC70\/ICEA S-95-658\u003cbr\u003eInstitute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstrction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003eColor-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e19\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness (Conductor):\u003c\/b\u003e0.760 mm \/ 0.030 inches\u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e0.130 mm \/ 0.005 inches\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e5.39 mm \/ 0.212 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.069 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e40 Amps at 60℃ \/ 50 Amps at 75℃ \/ 55 Amps at 90℃\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":40219861713075,"sku":"5402","price":0.86,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":40219861745843,"sku":"159200","price":0.74,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":40219861778611,"sku":"159201","price":0.86,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":40219861811379,"sku":"159202","price":0.79,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":40219861844147,"sku":"22477","price":0.94,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":40219861876915,"sku":"159196","price":0.88,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":40219861909683,"sku":"159198","price":0.78,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":40219861942451,"sku":"139810","price":0.86,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":40219861975219,"sku":"160760","price":0.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_3895e2e3-cfcc-4c9e-a33f-23b570c0d51b.jpg?v=1738617401"},{"product_id":"cto_250thhnstr","title":"250 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003eFeatures:\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e- AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e- ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003cbr\u003eSize: 250 MCM\u003cbr\u003eNumber of Strands: 37\u003cbr\u003eCross Section Area (mm2): 127.00\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.520 mm \/ 0.060 inches\u003cbr\u003eNylon Jacket Thickness: 0.200 mm \/ 0.008 inches\u003cbr\u003eOutside Diameter: 17.23 mm \/ 0.678 inches\u003cbr\u003eWeight: 0.903 lbs per ft\u003cbr\u003eAllowable Ampacity: 215 Amps at 60ºC \/ 255 Amps at 75ºC \/ 290 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":40227737206963,"sku":"6268","price":9.1,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":40227737239731,"sku":"108432","price":8.15,"currency_code":"USD","in_stock":false},{"title":"Brown","offer_id":40227737272499,"sku":"108431","price":6.78,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":40227737305267,"sku":"108446","price":6.79,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":40227737338035,"sku":"183839","price":7.17,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":40227737370803,"sku":"108430","price":6.73,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":40227737403571,"sku":"253064","price":8.47,"currency_code":"USD","in_stock":false},{"title":"White","offer_id":40227737436339,"sku":"253065","price":8.47,"currency_code":"USD","in_stock":false},{"title":"Yellow","offer_id":40227737501875,"sku":"108433","price":6.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_e553320c-93a7-46f3-8d1e-d1162374525e.jpg?v=1738617434"},{"product_id":"cto_300thhnstr","title":"300 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e- AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e- ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 300 MCM\u003cbr\u003eNumber of Strands: 37\u003cbr\u003eCross Section Area (mm2): 152.00\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.524 mm \/ 0.060 inches\u003cbr\u003eNylon Jacket Thickness: 0.203 mm \/ 0.008 inches\u003cbr\u003eOutside Diameter: 18.54 mm \/ 0.730 inches\u003cbr\u003eWeight: 1.06 lbs per ft\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":40241450025139,"sku":"22123","price":9.05,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":40241450057907,"sku":"108466","price":9.59,"currency_code":"USD","in_stock":false},{"title":"Brown","offer_id":40241450123443,"sku":"108458","price":8.36,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":40241450188979,"sku":"108464","price":8.41,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":40241450221747,"sku":"108465","price":9.59,"currency_code":"USD","in_stock":false},{"title":"Orange","offer_id":40241450287283,"sku":"108461","price":8.4,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":40241450352819,"sku":"220370","price":6.93,"currency_code":"USD","in_stock":false},{"title":"White","offer_id":40241450418355,"sku":"220371","price":6.93,"currency_code":"USD","in_stock":false},{"title":"Yellow","offer_id":40241450451123,"sku":"108463","price":8.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_8b58df0f-7e56-43a1-8c72-17d65e925204.jpg?v=1738617199"},{"product_id":"cto_400thhnstr","title":"400 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e- AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e- ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 400 MCM\u003cbr\u003eNumber of Strands: 37\u003cbr\u003eCross Section Area (mm2): 203.00\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.524 mm \/ 0.060 inches\u003cbr\u003eNylon Jacket Thickness: 0.203 mm \/ 0.008 inches\u003cbr\u003eOutside Diameter: 20.85 mm \/ 0.821 inches\u003cbr\u003eWeight: 1.332 lbs per ft\u003cbr\u003eAllowable Ampacity: 280 Amps at 60ºC \/ 335 Amps at 75ºC \/ 380 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":40241449992371,"sku":"11884","price":14.62,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":40241450090675,"sku":"299167","price":30.81,"currency_code":"USD","in_stock":false},{"title":"Brown","offer_id":40241450156211,"sku":"161801","price":12.52,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":40241450254515,"sku":"299168","price":30.81,"currency_code":"USD","in_stock":false},{"title":"Green","offer_id":40241450320051,"sku":"299169","price":30.81,"currency_code":"USD","in_stock":false},{"title":"Orange","offer_id":40241450385587,"sku":"161802","price":14.12,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":40241450483891,"sku":"246738","price":15.45,"currency_code":"USD","in_stock":false},{"title":"White","offer_id":40241450516659,"sku":"299170","price":30.81,"currency_code":"USD","in_stock":false},{"title":"Yellow","offer_id":40241450549427,"sku":"161803","price":12.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_a807426e-1154-4ea3-9915-2a712d66a1e2.jpg?v=1738617237"},{"product_id":"cto_600thhnstr","title":"600 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e- AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e- ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 600 MCM\u003cbr\u003eNumber of Strands: 61\u003cbr\u003eCross Section Area (mm2): 304.00\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.778 mm \/ 0.070 inches\u003cbr\u003eNylon Jacket Thickness: 0.229 mm \/ 0.009 inches\u003cbr\u003eOutside Diameter: 26.70 mm \/ 1.051 inches\u003cbr\u003eWeight: 1.99 lbs per ft\u003cbr\u003eAllowable Ampacity: 355 Amps at 60ºC \/ 420 Amps at 75ºC \/ 475 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":40241452646579,"sku":"36755","price":26.22,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":40241452679347,"sku":"108444","price":20.11,"currency_code":"USD","in_stock":false},{"title":"Brown","offer_id":40241452908723,"sku":"108440","price":23.62,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":40241452974259,"sku":"108443","price":25.17,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":40241453039795,"sku":"108445","price":13.78,"currency_code":"USD","in_stock":false},{"title":"Orange","offer_id":40241453170867,"sku":"108441","price":23.76,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":40241453203635,"sku":"220359","price":20.49,"currency_code":"USD","in_stock":false},{"title":"White","offer_id":40241453269171,"sku":"187888","price":20.11,"currency_code":"USD","in_stock":false},{"title":"Yellow","offer_id":40241453301939,"sku":"108442","price":23.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_60cb4797-46d7-4f29-a935-db4a45cc0ebd.jpg?v=1694450237"},{"product_id":"cto_700thhnstr","title":"750 MCM Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e- AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e- ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 750 MCM\u003cbr\u003eNumber of Strands: 61\u003cbr\u003eCross Section Area (mm2): 380.00\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.778 mm \/ 0.070 inches\u003cbr\u003eNylon Jacket Thickness: 0.229 mm \/ 0.009 inches\u003cbr\u003eOutside Diameter: 29.36 mm \/ 1.156 inches\u003cbr\u003eWeight: 2.468 lbs per ft\u003cbr\u003eAllowable Ampacity: 400 Amps at 60ºC \/ 475 Amps at 75ºC \/ 535 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":40241452712115,"sku":"3030","price":18.18,"currency_code":"USD","in_stock":false},{"title":"Blue","offer_id":40241452744883,"sku":"299292","price":82.0,"currency_code":"USD","in_stock":false},{"title":"Brown","offer_id":40241452777651,"sku":"299293","price":82.0,"currency_code":"USD","in_stock":false},{"title":"Gray","offer_id":40241452810419,"sku":"299294","price":82.0,"currency_code":"USD","in_stock":false},{"title":"Green","offer_id":40241452843187,"sku":"207544","price":34.64,"currency_code":"USD","in_stock":false},{"title":"Orange","offer_id":40241452875955,"sku":"172070","price":34.64,"currency_code":"USD","in_stock":false},{"title":"Red","offer_id":40241452941491,"sku":"299295","price":82.0,"currency_code":"USD","in_stock":false},{"title":"White","offer_id":40241453007027,"sku":"299296","price":82.0,"currency_code":"USD","in_stock":false},{"title":"Yellow","offer_id":40241453072563,"sku":"172071","price":34.64,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_1e435783-540b-442a-9a1a-b1dbe459f092.jpg?v=1738617224"},{"product_id":"cto_500thhnstr","title":"500 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003cbr\u003eNylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Underwriters Laboratories Standards UL-83, UL-1063, UL-758\u003cbr\u003e- AWM Spec 1316, 1317, 1318, 1319, 1320, 1321\u003cbr\u003e- ASTM Stranding Class B3, B8, B787\u003cbr\u003e- Federal Specification A-A-59544\u003cbr\u003e- Canadian Standards Association C22.2 No. 75\u003cbr\u003e- NEMA WC70\/ICEA S-95-658\u003cbr\u003e- Institute of Electrical and Electronics Engineers\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 500 MCM\u003cbr\u003eNumber of Strands: 37\u003cbr\u003eCross Section Area (mm2): 253.00\u003cbr\u003ePVC Insulation Thickness (Conductor): 1.520 mm \/ 0.060 inches\u003cbr\u003eNylon Jacket Thickness: 0.200 mm \/ 0.008 inches\u003cbr\u003eOutside Diameter: 22.91 mm \/ 0.902 inches\u003cbr\u003eWeight: 1.735 lbs per ft\u003cbr\u003eAllowable Ampacity: 320 Amps at 60ºC \/ 380 Amps at 75ºC \/ 430 Amps at 90ºC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":40241453105331,"sku":"1154","price":17.16,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":40241453138099,"sku":"108438","price":16.14,"currency_code":"USD","in_stock":false},{"title":"Brown","offer_id":40241453236403,"sku":"108435","price":16.06,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":40241453367475,"sku":"108439","price":14.62,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":40241453400243,"sku":"108447","price":15.52,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":40241453433011,"sku":"108436","price":16.04,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":40241453465779,"sku":"235635","price":16.14,"currency_code":"USD","in_stock":false},{"title":"White","offer_id":40241453498547,"sku":"200256","price":16.14,"currency_code":"USD","in_stock":false},{"title":"Yellow","offer_id":40241453531315,"sku":"108437","price":18.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_c265e946-8a30-4ca1-bd1d-ba6f7376839e.jpg?v=1738617302"},{"product_id":"cto_4thhnstr","title":"#4 Stranded Copper THHN Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003eTHHN and THWN is a multi-purpose building wire used in conduit and cable trays for service, feeders and branch circuits in commercial and industrial applications. It is also used as a conductor in NM-B, UF-B, SER, SEU and MC. Southwires THHN is rated for 600-Volt and has a heat capacity of up to 90Deg.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). 4 AWG THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90Deg or not to exceed 75Deg in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90Deg, or not to exceed 60Deg in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105Deg in dry locations.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUnderwriters Laboratories Standards UL-83, UL-1063, UL-758\n\u003cbr\u003eAWM Spec 1316, 1317, 1318, 1319, 1320, 1321\n\u003cbr\u003eASTM Stranding Class B3, B8, B787\n\u003cbr\u003eFederal Specification A-A-59544\n\u003cbr\u003eCanadian Standards Association C22.2 No. 75\n\u003cbr\u003eNEMA WC70\/ICEA S-95-658\n\u003cbr\u003eInstitute of Electrical and Electronics Engineers\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eSize:\u003c\/b\u003e 4 AWG\n\u003cbr\u003e\u003cb\u003eNumber of Strands:\u003c\/b\u003e 19\n\u003cbr\u003e\u003cb\u003eCross Section Area (mm2):\u003c\/b\u003e 21.2\n\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness (Conductor):\u003c\/b\u003e 1.020 mm \/ 0.040 inches\n\u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e 0.150 mm \/ 0.006 inches\n\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e 8.06 mm \/ 0.317 inches\n\u003cbr\u003e\u003cb\u003eWeight:\u003c\/b\u003e 0.166 lbs per ft\n\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 70 Amps at 60degC \/ 85 Amps at 75degC \/ 95 Amps at 90degC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black","offer_id":40257507360947,"sku":"6678","price":2.06,"currency_code":"USD","in_stock":true},{"title":"Blue","offer_id":40257507393715,"sku":"164953","price":1.95,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":40257507426483,"sku":"9547","price":2.0,"currency_code":"USD","in_stock":true},{"title":"Gray","offer_id":40257507459251,"sku":"254493","price":1.86,"currency_code":"USD","in_stock":true},{"title":"Green","offer_id":40257507492019,"sku":"13278","price":2.08,"currency_code":"USD","in_stock":true},{"title":"Orange","offer_id":40257507524787,"sku":"18266","price":1.94,"currency_code":"USD","in_stock":true},{"title":"Red","offer_id":40257507557555,"sku":"164952","price":1.91,"currency_code":"USD","in_stock":true},{"title":"White","offer_id":40257507590323,"sku":"164954","price":2.06,"currency_code":"USD","in_stock":true},{"title":"Yellow","offer_id":40257507623091,"sku":"24331","price":1.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/brown-stranded-thhn_cba51a94-8a3a-4f36-bc24-84c6c778da3f.jpg?v=1738617264"},{"product_id":"reel_14thhnsld","title":"#14 Solid Copper THHN Building Wire","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003eTHHN and THWN is a multi-purpose building wire used in conduit and cable trays for service, feeders and branch circuits in commercial and industrial applications. It is also used as a conductor in NM-B, UF-B, SER, SEU and MC. Southwires THHN is rated for 600-Volt and has a heat capacity of up to 90Deg.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eType THHN\/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC).Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90Deg or not to exceed 75Deg in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90Deg, or not to exceed 60Deg in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105Deg in dry locations.\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUnderwriters Laboratories Standards UL-83, UL-1063, UL-758\n\u003cbr\u003eAWM Spec 1316, 1317, 1318, 1319, 1320, 1321\n\u003cbr\u003eASTM Stranding Class B3, B8, B787\n\u003cbr\u003eFederal Specification A-A-59544\n\u003cbr\u003eCanadian Standards Association C22.2 No. 75\n\u003cbr\u003eNEMA WC70\/ICEA S-95-658\n\u003cbr\u003eInstitute of Electrical and Electronics Engineers\u003c\/p\u003e\n\n\u003chr\u003e\n\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eSize:\u003c\/b\u003e 14 AWG\n\u003cbr\u003e\u003cb\u003eStranding:\u003c\/b\u003e Solid\n\u003cbr\u003e\u003cb\u003eCross Section Area (mm2):\u003c\/b\u003e 2.08\n\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness (Conductor):\u003c\/b\u003e 0.380 mm \/ 0.015 inches\n\u003cbr\u003e\u003cb\u003eNylon Jacket Thickness:\u003c\/b\u003e 0.100 mm \/ 0.004 inches\n\u003cbr\u003e\u003cb\u003eOutside Diameter:\u003c\/b\u003e 2.57 mm \/ 0.101 inches\n\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 15 Amps at 60degC \/ 15 Amps at 75degC \/ 15 Amps at 90degC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Black \/ 500","offer_id":40325096931507,"sku":"15767","price":100.83,"currency_code":"USD","in_stock":true},{"title":"Black \/ 2500","offer_id":40325096964275,"sku":"225603","price":249.98,"currency_code":"USD","in_stock":false},{"title":"Blue \/ 500","offer_id":40325096997043,"sku":"15818","price":90.24,"currency_code":"USD","in_stock":true},{"title":"Blue \/ 2500","offer_id":40325097029811,"sku":"113000","price":327.24,"currency_code":"USD","in_stock":false},{"title":"Brown \/ 500","offer_id":40325097062579,"sku":"16326","price":64.07,"currency_code":"USD","in_stock":true},{"title":"Brown \/ 2500","offer_id":40325097095347,"sku":"113003","price":245.43,"currency_code":"USD","in_stock":false},{"title":"Gray \/ 500","offer_id":40325097128115,"sku":"20913","price":93.16,"currency_code":"USD","in_stock":true},{"title":"Gray \/ 2500","offer_id":40325097160883,"sku":"113005","price":245.75,"currency_code":"USD","in_stock":false},{"title":"Green \/ 500","offer_id":40325097193651,"sku":"21026","price":90.57,"currency_code":"USD","in_stock":true},{"title":"Green \/ 2500","offer_id":40325097226419,"sku":"236972","price":418.21,"currency_code":"USD","in_stock":false},{"title":"Orange \/ 500","offer_id":40325097259187,"sku":"27146","price":89.77,"currency_code":"USD","in_stock":true},{"title":"Orange \/ 2500","offer_id":40325097291955,"sku":"170544","price":489.91,"currency_code":"USD","in_stock":false},{"title":"Red \/ 500","offer_id":40325097324723,"sku":"28700","price":92.21,"currency_code":"USD","in_stock":true},{"title":"Red \/ 2500","offer_id":40325097357491,"sku":"225604","price":268.8,"currency_code":"USD","in_stock":true},{"title":"White \/ 500","offer_id":40325097423027,"sku":"27364","price":92.39,"currency_code":"USD","in_stock":true},{"title":"White \/ 2500","offer_id":40325097455795,"sku":"170541","price":303.62,"currency_code":"USD","in_stock":true},{"title":"Yellow \/ 500","offer_id":40325097488563,"sku":"34306","price":96.12,"currency_code":"USD","in_stock":true},{"title":"Yellow \/ 2500","offer_id":40325097521331,"sku":"170542","price":245.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/blue_20solid_20thhn_ce258919-e79f-49f8-898a-695489abcf58.png?v=1738617567"},{"product_id":"cto_6-3uf-nmcb","title":"6\/3 UF-B Underground Feeder and Direct Earth Burial Cable with Ground Cut to Order","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eUF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry \/ wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eASTM - B3 and B-8\u003cbr\u003eUL Standard 83\u003cbr\u003eUL Standard 493\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNational Electrical Code, NFPA 70, 2011 Edition\u003cbr\u003eRoHS\/REACH\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003e Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.\u003cbr\u003e\u003cb\u003eJacket: \u003c\/b\u003eSunlight, moisture and fungus resistant gray PVC.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e6 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e3\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.035 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.005 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e1.223 inches x .361 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.437 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 55 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40339750551731,"sku":"21687","price":4.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/6-3UFstranded.jpg?v=1673022575"},{"product_id":"cto_12-2mc","title":"12\/2 Metal Clad (MC) Cable with Ground, Aluminium Armor and Solid Copper Conductors Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eMetal Clad Cable may be used for branch, feeder and service distribution in commercial, industrial and multi-residential construction. They are suitable for installation in motion picture studios, theatres and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330. 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003eConductors and the wires are soft annealed copper to ASTM B3. PVC\/Nylon type THHN insulation in accordance to UL 83, flame resistant, meeting UL VW-1. Bare copper ground wire, sized in accordance with NEC and UL, with green THHN insulation. Conductors are cabled with grounding wires. A marker tape\/core protection tape combination assembles the core in an essentially round configuration. Interlocking galvanized steel tape armor applied directly over the core.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e - Meets UL 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003e - Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)\u003cbr\u003e - Meets UL 1569: Metal Clad Cables\u003cbr\u003e - Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords\u003cbr\u003e - Meets UL 2256: Wire and Cable Test Methods\u003cbr\u003e - Designated Type MC per NEC Article 330\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e - Size - \u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003e - Outside Diameter - \u003c\/b\u003e0.477 inches\u003cbr\u003e\u003cb\u003e - Ampere Rating THHN - \u003c\/b\u003e20\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657658708147,"sku":"289177","price":0.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/41oxZ0efcML._AC_SS450.jpg?v=1664566135"},{"product_id":"cto_6-2nm-b","title":"6\/2 NM-B Non-Metallic, Residential Indoor Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eNon-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eMeets or exceeds all applicable ASTM specifications\u003cbr\u003eUL Standard 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003eUL Standard 719: Non-Metallic Cables\u003cbr\u003eFederal Specification A-A-59544 and requirements of the NEC\u003cbr\u003eVoltage rating - 600 volts\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstrction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003eColor coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90℃C\u003cbr\u003e\u003cb\u003eSheath:\u003c\/b\u003e30 mil color coded PVC sheath rated 90℃C is applied over the completed assembly\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e6 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.76 mm \/ 0.029 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.13 mm \/ 0.005 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e8.1 x 17.3 mm \/ 0.31 x 0.68 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.255 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 55 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657659166899,"sku":"20784","price":3.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/2_wire_NM_Madwire_Photo.jpg?v=1743023822"},{"product_id":"cto_6-3nm-b","title":"6\/3 NM-B Non-Metallic, Residential Indoor Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eAPPLICATIONS:\u003c\/b\u003e\u003cbr\u003eNon-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSTANDARDS:\u003c\/b\u003e\u003cbr\u003eMeets or exceeds all applicable ASTM specifications\u003cbr\u003eUL Standard 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003eUL Standard 719: Non-Metallic Cables\u003cbr\u003eFederal Specification A-A-59544 and requirements of the NEC\u003cbr\u003eVoltage rating - 600 volts\u003c\/p\u003e\u003cp\u003e\u003cb\u003eCONSTRUCTION:\u003c\/b\u003e\u003cbr\u003eInsulation: Color coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90 degrees Celsius\u003cbr\u003eGround: Soft, bare copper solid per ASTM B3 and stranded per ASTM B3 and B8\u003cbr\u003eSheath: 30 mil color coded PVC sheath rated 90C is applied over the completed assembly\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSPECIFICATIONS:\u003c\/b\u003e\u003cbr\u003eSize: 6 AWG\u003cbr\u003eNumber of Conductors: 3\u003cbr\u003ePVC Insulation Thickness: 0.76 mm \/ 0.029 inches\u003cbr\u003eGround Wire Size: 10 AWG\u003cbr\u003eNylon Thickness: 0.13 mm \/ 0.005 inches\u003cbr\u003eNominal Cable Dimensions: 16.0 mm \/ 0.62 inches\u003cbr\u003eWeight per foot: 0.357 lbs\u003cbr\u003eAllowable Ampacity: 55 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657659199667,"sku":"21592","price":4.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/41OqDRdcNcL._SL1080.jpg?v=1743023735"},{"product_id":"cto_12-3mc","title":"12\/3 Metal Clad (MC) Cable with Ground, Aluminium Armor and Solid Copper Conductors Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eMetal Clad Cable may be used for branch, feeder and service distribution in commercial, industrial and multi-residential construction. They are suitable for installation in motion picture studios, theatres and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330. 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003eConductors and the wires are soft annealed copper to ASTM B3. PVC\/Nylon type THHN insulation in accordance to UL 83, flame resistant, meeting UL VW-1. Bare copper ground wire, sized in accordance with NEC and UL, with green THHN insulation. Conductors are cabled with grounding wires. A marker tape\/core protection tape combination assembles the core in an essentially round configuration. Interlocking galvanized steel tape armor applied directly over the core.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e - Meets UL 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003e - Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)\u003cbr\u003e - Meets UL 1569: Metal Clad Cables\u003cbr\u003e - Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords\u003cbr\u003e - Meets UL 2256: Wire and Cable Test Methods\u003cbr\u003e - Designated Type MC per NEC Article 330\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003e - Size - \u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003e - Outside Diameter - \u003c\/b\u003e0.509 inches\u003cbr\u003e\u003cb\u003e - Ampere Rating THHN: - \u003c\/b\u003e20 Amps\u003c\/p\u003e.","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657659232435,"sku":"287256","price":1.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/20KZ48_AS02.jpg?v=1664566139"},{"product_id":"cto_8-3nm-b","title":"8\/3 NM-B Non-Metallic, Residential Indoor Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eNon-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eMeets or exceeds all applicable ASTM specifications\u003cbr\u003eUL Standard 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003eUL Standard 719: Non-Metallic Cables\u003cbr\u003eFederal Specification A-A-59544 and requirements of the NEC\u003cbr\u003eVoltage rating - 600 volts\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003eColor coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90 degrees Celsius.\u003cbr\u003e\u003cb\u003eGround:\u003c\/b\u003e Soft bare copper per ASTM B3\u003cbr\u003e\u003cb\u003eSheath:\u003c\/b\u003e 30 mil color coded PVC sheath rated 90 degrees Celsius is applied over the completed assembly\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003cbr\u003eSize:\u003c\/b\u003e 8 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e 3 +1 ground\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e 0.76 mm \/ 0.029 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e 10 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e 0.13mm \/ 0.005 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e 14.2mm \/ 0.55 inches\u003cbr\u003e\u003cb\u003eWeight per foot:\u003c\/b\u003e 0.254 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 40 amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662509235,"sku":"37876","price":3.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/71pIPDm7aiL._SL1500.jpg?v=1743023988"},{"product_id":"cto_8-2nm-b","title":"8\/2 NM-B Non-Metallic, Residential Indoor Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eNon-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eMeets or exceeds all applicable ASTM specifications\u003cbr\u003eUL Standard 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003eUL Standard 719: Non-Metallic Cables\u003cbr\u003eFederal Specification A-A-59544 and requirements of the NEC\u003cbr\u003eVoltage rating - 600 volts\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003eColor coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90℃C\u003cbr\u003e\u003cb\u003eSheath:\u003c\/b\u003e30 mil color coded PVC sheath rated 90℃C is applied over the completed assembly\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.76 mm \/ 0.029 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.13 mm \/ 0.005 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e 6.9 mm x 15 mm \/ .27 x 0.59 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.186 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 40 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662476467,"sku":"37011","price":2.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/71pIPDm7aiL._SL1500.jpg?v=1743023988"},{"product_id":"cto_12-2uf-nmcb","title":"12\/2 UF-B Underground Feeder and Direct Earth Burial Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eUF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry \/ wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eASTM - B3 and B-8\u003cbr\u003eUL Standard 83\u003cbr\u003eUL Standard 493\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNational Electrical Code, NFPA 70, 2011 Edition\u003cbr\u003eRoHS\/REACH\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003e Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.\u003cbr\u003e\u003cb\u003eJacket:\u003c\/b\u003eSunlight, moisture and fungus resistant gray PVC.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.030 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.005 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e.463 inches x .183 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.95 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 20 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662542003,"sku":"14367","price":0.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/31at9uCqllL._AC_SX466_5dfc0a9f-c6b4-4a1f-af32-34454714ce73.jpg?v=1664565461"},{"product_id":"cto_12-4mc","title":"12\/4 Metal Clad (MC) Cable with Ground, Aluminium Armor and Solid Copper Conductors Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eMetal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003eSolid conductors and the wires for stranded conductors are soft annealed copper to ASTM B3. PVC\/Nylon type THHN insulation in accordance to UL 83, flame resistant, meeting UL VW-1. Bare copper ground wire, sized in accordance with NEC and UL, with green THHN insulation. Conductors are cabled with grounding wires. A marker tape\/core protection tape combination assembles the core in an essentially round configuration. Interlocking galvanized steel tape armor applied directly over the core. flame test.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Meets UL 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003e- Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)\u003cbr\u003e- Meets UL 1569: Metal Clad Cables\u003cbr\u003e- Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords\u003cbr\u003e- Meets UL 2256: Wire and Cable Test Methods\u003cbr\u003e- Designated Type MC per NEC Article 330\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 12 AWG\u003cbr\u003eConductors: 4 + 1 Ground\u003cbr\u003eOutside Diameter: 0.544 Inches\u003cbr\u003eAmpere Rating THHN: 20\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662574771,"sku":"284279","price":2.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/111NZm92IFL.jpg?v=1743013581"},{"product_id":"cto_10-2uf-nmcb","title":"10\/2 UF-B Underground Feeder and Direct Earth Burial Cable with Ground Cut to Order","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eUF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry \/ wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eASTM - B3 and B-8\u003cbr\u003eUL Standard 83\u003cbr\u003eUL Standard 493\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNational Electrical Code, NFPA 70, 2011 Edition\u003cbr\u003eRoHS\/REACH\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003e Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.\u003cbr\u003e\u003cb\u003eJacket: \u003c\/b\u003eSunlight, moisture and fungus resistant gray PVC.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.024 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.004 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e0.518 inches x 0.215 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.178 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 33 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662607539,"sku":"28794","price":1.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/southwire-outdoor-electrical-wires-13056799-64_600.jpg?v=1664565490"},{"product_id":"cto_12-3uf-nmcb","title":"12\/3 UF-B Underground Feeder and Direct Earth Burial Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eUF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry \/ wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eASTM - B3 and B-8\u003cbr\u003eUL Standard 83\u003cbr\u003eUL Standard 493\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNational Electrical Code, NFPA 70, 2011 Edition\u003cbr\u003eRoHS\/REACH\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003e Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.\u003cbr\u003e\u003cb\u003eJacket:\u003c\/b\u003eSunlight, moisture and fungus resistant gray PVC.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e3\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.030 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e12 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.004 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e.626 inches x .183 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.129 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 20 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662673075,"sku":"6288","price":1.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/s-l300.jpg?v=1664565505"},{"product_id":"cto_4-3nm-b","title":"4\/3 NM-B Non-Metallic, Residential Indoor Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eNon-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Meets or exceeds all applicable ASTM specifications\u003cbr\u003e- UL 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003e- UL 719: Non-Metallic Cables\u003cbr\u003e- Federal Specification A-A-59544 and requirements of the NEC.\u003cbr\u003e- Voltage rating - 600 volts.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 4 AWG\u003cbr\u003eNumber of Conductors: 3 + 1 Ground\u003cbr\u003eGround Wire Size: 8 AWG\u003cbr\u003eNominal Cable Dimensions: .150mils\u003cbr\u003eWeight per foot: 0.556 lbs\u003cbr\u003eAllowable Ampacity: 70 Amps @ 30°C PER NEC\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662640307,"sku":"101242","price":12.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/4_3nm-b_cto-1.jpg?v=1679523906"},{"product_id":"cto_8-2uf-nmcb","title":"8\/2 UF-B Underground Feeder and Direct Earth Burial Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eUF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry \/ wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eASTM - B3 and B-8\u003cbr\u003eUL Standard 83\u003cbr\u003eUL Standard 493\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNational Electrical Code, NFPA 70, 2011 Edition\u003cbr\u003eRoHS\/REACH\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003e Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.\u003cbr\u003e\u003cb\u003eJacket:\u003c\/b\u003eSunlight, moisture and fungus resistant gray PVC.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.035 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.005 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e0.678 inches x 0.302 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.222 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 40 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662705843,"sku":"37118","price":2.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/8-2ufwire.jpg?v=1672425732"},{"product_id":"cto_10-3uf-nmcb","title":"10\/3 UF-B Underground Feeder and Direct Earth Burial Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eUF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry \/ wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eASTM - B3 and B-8\u003cbr\u003eUL Standard 83\u003cbr\u003eUL Standard 493\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNational Electrical Code, NFPA 70, 2011 Edition\u003cbr\u003eRoHS\/REACH\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003e Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.\u003cbr\u003e\u003cb\u003eJacket:\u003c\/b\u003eSunlight, moisture and fungus resistant PVC.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e3\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.024 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.004 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e0.727 inches x 0.215 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.102 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 30 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662836915,"sku":"20013","price":1.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/21QuOo6H4TL.jpg?v=1743013074"},{"product_id":"cto_8-3uf-nmcb","title":"8\/3 UF-B Underground Feeder and Direct Earth Burial Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eUF-B is an underground feeder and branch circuit wiring cable. It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry \/ wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011. UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eASTM - B3 and B-8\u003cbr\u003eUL Standard 83\u003cbr\u003eUL Standard 493\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNational Electrical Code, NFPA 70, 2011 Edition\u003cbr\u003eRoHS\/REACH\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstrction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003e Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.\u003cbr\u003e\u003cb\u003eJacket:\u003c\/b\u003eSunlight, moisture and fungus resistant gray PVC.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e8 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e3\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.035 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e#8 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.005 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e1.059 inches x 0.319 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.304 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 40 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657662804147,"sku":"37956","price":3.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/6-3UFstranded_779d5af4-1f9a-46e1-aa43-bf6271ce4d2c.jpg?v=1674166986"},{"product_id":"cto_6-2uf-nmcb","title":"6\/2 UF-B Underground Feeder and Direct Earth Burial Cable with Ground Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eType UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003eASTM - B3 and B-8\u003cbr\u003eUL Standard 83\u003cbr\u003eUL Standard 493\u003cbr\u003eFederal Specification A-A-59544\u003cbr\u003eNational Electrical Code, NFPA 70, 2011 Edition\u003cbr\u003eRoHS\/REACH\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstrction:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eInsulation:\u003c\/b\u003e Polyvinyl Chloride (PVC) with a nylon covering. Color coded phase identification.\u003cbr\u003e\u003cb\u003eJacket:\u003c\/b\u003eSunlight, moisture and fungus resistant gray PVC.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003e\u003cb\u003eSize:\u003c\/b\u003e6 AWG\u003cbr\u003e\u003cb\u003eNumber of Conductors:\u003c\/b\u003e2\u003cbr\u003e\u003cb\u003ePVC Insulation Thickness:\u003c\/b\u003e0.035 inches\u003cbr\u003e\u003cb\u003eGround Wire Size:\u003c\/b\u003e10 AWG\u003cbr\u003e\u003cb\u003eNylon Thickness:\u003c\/b\u003e0.005 inches\u003cbr\u003e\u003cb\u003eNominal Cable Dimensions:\u003c\/b\u003e0.73 inches x 0.338 inches\u003cbr\u003e\u003cb\u003eWeight per Foot:\u003c\/b\u003e 0.303 lbs\u003cbr\u003e\u003cb\u003eAllowable Ampacity:\u003c\/b\u003e 55 Amps\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40657663262899,"sku":"20868","price":3.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/UF-B-Cable.jpg?v=1685722480"},{"product_id":"cto_10-4mc","title":"10\/4 Metal Clad (MC) Cable with Ground, Aluminium Armor and Solid Copper Conductors Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003cbr\u003eMetal Clad Cable may be used for branch, feeder and service for distribution in commercial, industrial, and multi-residential construction. They are suitable for installation in motion picture studios, theaters, and places of assembly (100 people or more) per NEC Articles 230.43, 300.22(C), 330, 396, 518, 520, 530 and 645. These cables may be installed in approved raceways and as open runs of cable on a messenger. They may be installed exposed, concealed or in cable tray and may be run in spaces used for environmental air in accordance with NEC Article 300.22(C) ONLY.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003cbr\u003eSolid conductors and the wires for stranded conductors are soft annealed copper to ASTM B3. PVC\/Nylon type THHN insulation in accordance to UL 83, flame resistant, meeting UL VW-1. Bare copper ground wire, sized in accordance with NEC and UL, with green THHN insulation. Conductors are cabled with grounding wires. A marker tape\/core protection tape combination assembles the core in an essentially round configuration. Interlocking galvanized steel tape armor applied directly over the core. flame test.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- Meets UL 83: Thermoplastic Insulated Wires and Cables\u003cbr\u003e- Tested to UL 1479: Fire Tests of Through-Penetration Firestops for one, two or three hour fire rated assemblies (for cables up to #2 AWG)\u003cbr\u003e- Meets UL 1569: Metal Clad Cables\u003cbr\u003e- Meets UL 1581: Reference Standard for Electrical Wires, Cables, and Flexible Cords\u003cbr\u003e- Meets UL 2256: Wire and Cable Test Methods\u003cbr\u003e- Designated Type MC per NEC Article 330\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 10 AWG\u003cbr\u003eOutside Diameter: 0.628 inches\u003cbr\u003eAmpere Rating THHN: 30\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40669611688115,"sku":"285407","price":5.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/products\/MCLite_Solid.jpg?v=1664566136"},{"product_id":"cto_1000xhhw-al","title":"1000 MCM XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 1000 MCM\u003cbr\u003eNumber of Strands: 58\u003cbr\u003eInsulation Thickness: 0.080 inches\u003cbr\u003eOutside Diameter: 1.220 inches\u003cbr\u003eWeight: 1.063 lbs\/foot\u003cbr\u003eAmpacity: 500 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40878017708211,"sku":"74739","price":6.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/11WzPabVXnL.jpg?v=1743032788"},{"product_id":"cto_4xhhw-al","title":"4 AWG XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 4 AWG\u003cbr\u003eNumber of Strands: 7\u003cbr\u003eInsulation Thickness: 0.045 inches\u003cbr\u003eOutside Diameter: 0.303 inches\u003cbr\u003eWeight: 0.055 lbs\/foot\u003cbr\u003eAmpacity: 75 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063676595,"sku":"3787","price":0.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/21W83fwzgML_1_2ca5071d-2bd5-4627-9757-a276d2a4b504.jpg?v=1743013679"},{"product_id":"cto_2-0xhhw-al","title":"2\/0 AWG XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 2\/0 AWG\u003cbr\u003eNumber of Strands: 18\u003cbr\u003eInsulation Thickness: 0.055 inches\u003cbr\u003eOutside Diameter: 0.486 inches\u003cbr\u003eWeight: 0.157 lbs\/foot\u003cbr\u003eAmpacity: 150 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063709363,"sku":"24165","price":1.14,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/21W83fwzgML_31967c82-2da9-4f0d-ac03-a79faaced039.jpg?v=1743099695"},{"product_id":"cto_250xhhw-al","title":"250 MCM XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 250 MCM\u003cbr\u003eNumber of Strands: 35\u003cbr\u003eInsulation Thickness: 0.065 inches\u003cbr\u003eOutside Diameter: 0.650 inches\u003cbr\u003eWeight: 0.286 lbs\/foot\u003cbr\u003eAmpacity: 230 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063742131,"sku":"7720","price":1.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/11WzPabVXnL1.jpg?v=1743099773"},{"product_id":"cto_600xhhw-al","title":"600 MCM XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 600 MCM\u003cbr\u003eNumber of Strands: 58\u003cbr\u003eInsulation Thickness: 0.080 inches\u003cbr\u003eOutside Diameter: 0.973 inches\u003cbr\u003eWeight: 0.660 lbs\/foot\u003cbr\u003eAmpacity: 385 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063840435,"sku":"40446","price":4.72,"currency_code":"USD","in_stock":true}]},{"product_id":"cto_400xhhw-al","title":"400 MCM XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 400 MCM\u003cbr\u003eNumber of Strands: 35\u003cbr\u003eInsulation Thickness: 0.065 inches\u003cbr\u003eOutside Diameter: 0.789 inches\u003cbr\u003eWeight: 0.439 lbs\/foot\u003cbr\u003eAmpacity: 305 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063774899,"sku":"42139","price":4.92,"currency_code":"USD","in_stock":true}]},{"product_id":"cto_1xhhw-al","title":"1 AWG XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 1 AWG\u003cbr\u003eNumber of Strands: 18\u003cbr\u003eInsulation Thickness: 0.055 inches\u003cbr\u003eOutside Diameter: 0.409 inches\u003cbr\u003eWeight: 0.105 lbs\/foot\u003cbr\u003eAmpacity: 115 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063873203,"sku":"21891","price":0.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/21W83fwzgML_1.jpg?v=1743013658"},{"product_id":"cto_300xhhw-al","title":"300 MCM XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 300 MCM\u003cbr\u003eNumber of Strands: 35\u003cbr\u003eInsulation Thickness: 0.065 inches\u003cbr\u003eOutside Diameter: 0.700 inches\u003cbr\u003eWeight: 0.337 lbs\/foot\u003cbr\u003eAmpacity: 255 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063905971,"sku":"22506","price":3.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/11WzPabVXnL1_fd275b05-77ce-49fb-b5be-95b6c847f5e8.jpg?v=1743099877"},{"product_id":"cto_4-0xhhw-al","title":"4\/0 AWG XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 4\/0 AWG\u003cbr\u003eNumber of Strands: 18\u003cbr\u003eInsulation Thickness: 0.055 inches\u003cbr\u003eOutside Diameter: 0.585 inches\u003cbr\u003eWeight: 0.238 lbs\/foot\u003cbr\u003eAmpacity: 205 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063938739,"sku":"22403","price":1.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/21W83fwzgML_2.jpg?v=1743013771"},{"product_id":"cto_6xhhw-al","title":"6 AWG XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 6 AWG\u003cbr\u003eNumber of Strands: 7\u003cbr\u003eInsulation Thickness: 0.045 inches\u003cbr\u003eOutside Diameter: 0.259 inches\u003cbr\u003eWeight: 0.038 lbs\/foot\u003cbr\u003eAmpacity: 60 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880063971507,"sku":"31741","price":0.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/21W83fwzgML_18cbbd1b-a221-4709-9ebf-46ab53516ec3.jpg?v=1743013621"},{"product_id":"cto_1-0xhhw-al","title":"1\/0 AWG XHHW-2 Aluminum Building Wire Cut to Order","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eApplications\u003c\/b\u003e\u003cbr\u003eXHHW-2 are primarily used in air duct, conduit or recognized raceways for services, feeders and branch circuit wiring as specified in the National Electrical Code. When used as Type THHN or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90°C. When used as Type THWN-2 or TWN75, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C when exposed to oil or coolant. Voltage for all applications is 600 volts. This cable should be installed without application of pulling lubricant.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003cbr\u003e- UL 44\u003cbr\u003e- ASTM B800 and B801\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003cbr\u003eSize: 1\/0 AWG\u003cbr\u003eNumber of Strands: 18\u003cbr\u003eInsulation Thickness: 0.055 inches\u003cbr\u003eOutside Diameter: 0.446 inches\u003cbr\u003eWeight: 0.128 lbs\/foot\u003cbr\u003eAmpacity: 135 amps at 90 degress Celcius\u003c\/p\u003e","brand":"wirenco","offers":[{"title":"Default Title","offer_id":40880064004275,"sku":"3072","price":0.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8590\/2515\/files\/21W83fwzgML.jpg?v=1741629204"}],"url":"https:\/\/shopwirenco.com\/collections\/cable-wires.oembed?page=4","provider":"Wirenco","version":"1.0","type":"link"}