Tork EPC-A Conduit Mount Photo Sensor
Couldn't load pickup availability
Scheduling 56 on and Off Set Points Provide Individual Programs for Each Day of the Week; Minimum Setting is 1 Minute; Light Level Activation Turn on is User Settable from 1 to 100 Footcandle; Turn Off is a Maximum of 2 Times Turn on Level; Each Channel has an Independent Setting; Includes a User Settable Delay before on and Off Between 1 to 90 Seconds; Remote Override On: Each Channel has Independent Input for a Maintained Dry-Contact Closure; May Use Tork Model SS410 and Trp-24B for Timed Override; May Use with Occupancy Sensor with Dry Contacts as Override; Manual Override Until the Next Regularly Scheduled ON or OFF, Automatic Operation then Resumes; Momentary Contact DGUM100A 2 Second Contact Closure on and Off to Control Mechanically Held Contactors or Latching Relays; Daylight Saving Automatic Adjustment; Leap Year Automatic Compensation; Clock Format; Power Outage Backup Permanent Schedule Retention; Enhanced Switching Inrush Current Limiting Technology Protects Relay Contacts for Extended Life with Zero Cross Type Switching
Specifications:
Mounting: 1/2 Inch
Mounting Position: 180 Degree Swivel
Enclosure Material: Lexan
Size: 1-5/8 Inch Dia x 4-7/8 Inch H
Application: Parking Lot Lighting, Walkways, Building Exteriors, Floodlighting